ATM Thermal Cut-Out ATM Thermal Cut-Out temperature-operated protector or thermal switch for thermal control and overtemperature protection in electrical equipment. Check operating temperature and contact ratings in the technical drawings.
Product Information & Specifications ATM electrical characteristics Electrical rating: AC 250 V / 16 A, 50/60 Hz, 10,000 cycles; AC 125 V / 16 A, 100,000 cycles
Contact resistance: ≤ 50 mΩ
Complete technical table and diagrams below. Tap the image to enlarge for detailed specifications.
41
ATM THERMAL CUT-OUT
HOME
EMAIL
When the protected equipment heats up, warmth reaches the bimetallic element. At the set
operating temperature, the bimetal opens the moving contact and interrupts the circuit.
When the temperature drops to the rated reset temperature, the bimetal returns
automatically and closes the circuit.
ATM
~AC
PTC
ATM
~AC
PTC
When the temperature rises, the contacts open and current flows through the PTC element.
The PTC heats above the rated reset temperature and keeps the circuit open. After power
is switched off and the bimetal cools to its reset temperature, the contacts close again and
restore the protection circuit.
Before operation
(Contact connected)
After operation
(Contact disconnected)
ELECTRIC THERMAL EFFECT
5
4
33
26.5
5
5
4
33
26.5
5
7
5
17
11
3.2
Auto-Reset Type (ATM-01) Products
Turn off to reset (ATM-01P) Products
WORKING PRINCIPLE
KEY FEATURES OF THE PRODUCT
DIMENSIONS(MM)
Power supply
Load
Operating
Power supply
Load
Stopped
Current (A)
Handles current up to 16A
Long service life: 100000 cycles
Fast operation
Fast thermal response
Heat-resistant ceramic support
42
ATM PARAMETERS
HOME
EMAIL
The product should be stored in a ventilated, clean, dry and non-corrosive place with relative humidity
less than 90% and ambient temperature below 40°C.
In the process of installation and use, the shrapnel and the temperature sensing part must not be touched.
Otherwise, the temperature of the thermostat will be inaccurate and the contact is not good enough to work.
TUV
ATM-01(01P)-60
℃
ATM-01(01P)-65
℃
ATM-01(01P)-70
℃
ATM-01(01P)-75℃
ATM-01(01P)-80℃
ATM-01(01P)-85℃
ATM-01(01P)-90℃
ATM-01(01P)-95℃
ATM-01(01P)-100℃
ATM-01(01P)-105℃
ATM-01(01P)-110℃
ATM-01(01P)-115℃
ATM-01(01P)-120℃
ATM-01(01P)-125℃
ATM-01(01P)-130℃
ATM-01(01P)-135℃
ATM-01(01P)-140℃
ATM-01(01P)-145℃
ATM-01(01P)-150℃
UL
CQC
60±5
65±5
70±5
75±5
80±5
85±5
90±5
95±5
100±5
105±5
110±5
115±5
120±5
125±5
130±5
135±5
140±5
145±5
150±5
45±8
48±10
50±12
53±15
55±15
60±15
65±15
65±15
70±15
75±15
75±15
80±15
85±15
85±15
90±15
95±15
100±15
100±15
105±15
110℃
115℃
120℃
125℃
130℃
135℃
140℃
145℃
150℃
155℃
160℃
165℃
170℃
175℃
180℃
185℃
190℃
195℃
200℃
Overheating protection for hair dryers and curling irons
Heater, popcorn maker, electric oven
Heating fan, etc.
AC250V/16A 50/60HZ 10000cycles
AC125V/16A 100000cycles
≤50m
Ω
Normally closed (auto reset
)
Normally closed (manual reset)
Certification
(1) Reset temperature for reference
(2) ● = obtained; ○ = not obtained
ATM THERMAL CUT - OUT SERIES
Electric characteristic
Contact resistance
Temperature characteristic
PN
Action temperature
Reset temp
(
℃
)
Highest ambient temp
PARAMETER LIST
ATM
APPLICATION
STORAGE AND INSTALLATION PRECAUTIONS
ATM — Electrical characteristics AC 250 V / 16 A (50/60 Hz), 10,000 cycles · AC 125 V / 16 A, 100,000 cycles Contact resistance ≤ 50 mΩ
Part No. Action temp. (°C) Reset temp. (°C) Max ambient temp. Automatic reset Manual reset ATM-01(01P)-60℃ 60±5 45±8 110℃ ATM-01(01P)-65℃ 65±5 48±10 115℃ ATM-01(01P)-70℃ 70±5 50±12 120℃ ATM-01(01P)-75℃ 75±5 53±15 125℃ ATM-01(01P)-80℃ 80±5 55±15 130℃ ATM-01(01P)-85℃ 85±5 60±15 135℃ ATM-01(01P)-90℃ 90±5 65±15 140℃ ATM-01(01P)-95℃ 95±5 65±15 145℃ ATM-01(01P)-100℃ 100±5 70±15 150℃ ATM-01(01P)-105℃ 105±5 75±15 155℃ ATM-01(01P)-110℃ 110±5 75±15 160℃ ATM-01(01P)-115℃ 115±5 80±15 165℃ ATM-01(01P)-120℃ 120±5 85±15 170℃ ATM-01(01P)-125℃ 125±5 85±15 175℃ ATM-01(01P)-130℃ 130±5 90±15 180℃ ATM-01(01P)-135℃ 135±5 95±15 185℃ ATM-01(01P)-140℃ 140±5 100±15 190℃ ATM-01(01P)-145℃ 145±5 100±15 195℃ ATM-01(01P)-150℃ 150±5 105±15 200℃
Storage and installation precautions Storage conditions Store in a ventilated, clean, dry and non-corrosive environment at relative humidity below 90% and ambient temperature below 40°C. Handling During installation, do not touch the spring plate or temperature-sensing component; doing so can affect temperature accuracy and contact operation. For confirmation of specifications, availability and suitable application, please contact our sales team.