RLE logoRongli Electronics
Products / Circuit Protection / Overtemperature Protection / Thermal Protectors & Cut-Outs / KSD05 Thermal Protector
← Back to Thermal Protectors & Cut-Outs

KSD05 Thermal Protector

KSD05 Thermal Protector temperature-operated protector or thermal switch for thermal control and overtemperature protection in electrical equipment. Check operating temperature and contact ratings in the technical drawings.

Product Information & Specifications

KSD05 electrical characteristics
Electrical rating: AC 250 V / 5 A; AC 115 V / 8 A; DC 24 V / 10 A
Contact resistance: ≤ 50 mΩ

Complete technical table and diagrams below. Tap the image to enlarge for detailed specifications.

39 KSD05 THERMAL PROTECTOR HOME EMAIL Note: Type specification, color, length, sleeve specification, length of tin-plated copper wire can be customized according to customer requirements 3.2 30 15 7 L 7 . 1 15 3.5 L Temperature rise : Heat is transferred to bimetallic strip to reach the operating temperature value, and the contacts are disconnected. Temperature drop: Bimetallic strip quickly restored to original state, contact closed and circuit connected. 7.2 3.8 16 L 140 ℃ 100 ℃ 130 ℃ 120 ℃ 110 ℃ 90 ℃ 80 ℃ 70 ℃ 60 ℃ Often Open Type Often Close Type Normally Open Normally Closed Before Action ( Contact Connection ) After Action ( Contact Disconnection ) After Action ( Contact Connection ) Before Action ( Contact Disconnection ) Temperature rise: Emperature rise: heat is transferred to bimetallic strip to reach the action temperature value. Temperature drop: The bimetallic strip is restored to its original state, the contacts are disconnected, and the circuit is disconnected. 150 ℃ Current And Time Curve Chart Plastic Case Iron Case Plastic Case CURRENT AND TIME CURVE CHART Mylar sleeve Time (s) Current (A) Current (A) -OPERATING TEMP. DROP DUE TO CURRENT DIMENSIONS(MM) PARAMETER LIST KEY FEATURES OF THE PRODUCT Compact size and fast operation PBT or metal case with epoxy sealing Automatically resetting bimetallic strip Resistant to moisture, dust and varnish impregnation Fast thermal response Customization available to customer requirements
40 KSD05 PARAMETERS HOME EMAIL TUV KSD060**** KSD065**** KSD070**** KSD075**** KSD080**** KSD085**** KSD090**** KSD095**** KSD0100**** KSD105**** KSD110**** KSD115**** KSD120**** KSD125**** KSD130**** KSD135**** KSD140**** KSD145**** KSD150**** UL CQC 60±5 65±5 70±5 75±5 80±5 85±5 90±5 95±5 100±5 105±5 110±5 115±5 120±5 125±5 130±5 135±5 140±5 145±5 150±5 45±8 48±10 50±12 53±15 55±15 60±15 65±15 70±15 70±15 75±15 75±15 80±15 85±15 85±15 90±15 95±15 100±15 100±15 105±15 AC250V/5A; AC115V/8A; DC24V/10A ≤50m Ω 110 ℃ 115℃ 120℃ 125℃ 130℃ 135℃ 140℃ 145℃ 150℃ 155℃ 160℃ 165℃ 170℃ 175℃ 180℃ 180℃ 180℃ 180℃ 180℃ Motor Protection Battery Protection Transformer Protection Charger Protection Heating Pad Temperature Control Power Protection Pcb Circuit Board Protection Led Lamp Tube, Bulb Protection - - - - - - - - - - - - - - - - - - - - - - - - Electric characteristic Contact resistance Temperature characteristic PN Action temperature Reset temp ( ℃ ) Highest ambient temp Normally closed Plastic case Iron case Plastic case Iron case Normally open Certification (1) Reset temp for reference (2) ●=obtained ○ =no obtained KSD THERMAL PROTECTOR SERIES The product should be stored in a ventilated, clean, dry and non-corrosive place with relative humidity less than 90% and ambient temperature below 40 ℃ . No sharp tools should be used to crush the protectors. Do not use gravity to beat the protector. The protector shall be installed at the sensitive point of temperature rise of the protected object, and its temperature sensing surface shall be in close contact with the protected part effectively or directly oriented to the protected area. APPLICATION STORAGE AND INSTALLATION PRECAUTIONS PARAMETER LIST KSD Marked surface Heat source Sensing surface
KSD05 — Electrical characteristicsAC 250 V / 5 A · AC 115 V / 8 A · DC 24 V / 10 AContact resistance ≤ 50 mΩ
Part No.Action temp. (°C)Reset temp. (°C)Max ambient temp.N.C. plasticN.C. metalN.O. plasticN.O. metalTUVULCQC
KSD060****60±545±8110℃-
KSD065****65±548±10115℃-
KSD070****70±550±12120℃-
KSD075****75±553±15125℃-
KSD080****80±555±15130℃-
KSD085****85±560±15135℃-
KSD090****90±565±15140℃-
KSD095****95±570±15145℃-
KSD0100****100±570±15150℃-
KSD105****105±575±15155℃-
KSD110****110±575±15160℃-
KSD115****115±580±15165℃-
KSD120****120±585±15170℃-
KSD125****125±585±15175℃-
KSD130****130±590±15180℃-
KSD135****135±595±15180℃-
KSD140****140±5100±15180℃-
KSD145****145±5100±15180℃-
KSD150****150±5105±15180℃-

Storage and installation precautions

Storage conditions
Store in a ventilated, clean, dry and non-corrosive environment at relative humidity below 90% and ambient temperature below 40°C.
Installation
Install the protector at a temperature-sensitive point, keeping the sensing surface in effective contact with the protected part or facing the protected area.
Handling
Do not crush the protector with sharp tools. Do not strike the protector.

For confirmation of specifications, availability and suitable application, please contact our sales team.