KSD02 Thermal Protector temperature-operated protector or thermal switch for thermal control and overtemperature protection in electrical equipment. Check operating temperature and contact ratings in the technical drawings.
Electrical rating: AC 250 V / 2 A; AC 115 V / 3 A; DC 48 V / 3 A
Contact resistance: ≤ 50 mΩ
Complete technical table and diagrams below. Tap the image to enlarge for detailed specifications.
Operating temperature drop due to currentCurrent (A) · Temperature drop (°C)
Current and Time Curve ChartHorizontal axis: Time (s) · Vertical axis: Current (A)
KSD02 — Electrical characteristicsAC 250 V / 2 A · AC 115 V / 3 A · DC 48 V / 3 AContact resistance ≤ 50 mΩ
Part No.
Action temp. (°C)
Reset temp. (°C)
Max ambient temp.
N.C. plastic
N.C. metal
N.O. plastic
N.O. metal
TUV
UL
CQC
KSD040****
40±5
≥30
90℃
--
KSD045****
45±5
≥33
95℃
--
KSD050****
50±5
≥35
100℃
--
KSD055****
55±5
42±6
105℃
--
KSD060****
60±5
45±8
110℃
--
KSD065****
65±5
48±10
115℃
--
KSD070****
70±5
50±12
120℃
--
KSD075****
75±5
53±14
125℃
--
KSD080****
80±5
55±15
130℃
--
KSD085****
85±5
60±15
135℃
--
KSD090****
90±5
65±15
140℃
--
KSD095****
95±5
70±15
145℃
--
KSD100****
100±5
70±15
150℃
--
KSD105****
105±5
75±15
155℃
--
KSD110****
110±5
75±15
160℃
--
KSD115****
115±5
80±15
165℃
--
KSD120****
120±5
85±15
170℃
--
KSD125****
125±5
85±15
175℃
--
KSD130****
130±5
90±15
180℃
--
KSD135****
135±5
95±15
180℃
--
KSD140****
140±5
100±15
180℃
--
KSD145****
145±5
100±15
180℃
--
KSD150****
150±5
105±15
180℃
--
Storage and installation precautions
Storage conditions
Store in a ventilated, clean, dry and non-corrosive environment at relative humidity below 90% and ambient temperature below 40°C.
Installation
Install the protector at a temperature-sensitive point, keeping the sensing surface in effective contact with the protected part or facing the protected area.
Handling
Do not crush the protector with sharp tools. Do not strike the protector.
For confirmation of specifications, availability and suitable application, please contact our sales team.