BTW Series Thermal Fuse BTW Series Thermal Fuse thermal cut-off fuse for one-time overtemperature protection of electrical and electronic equipment. Compare rated operating temperature and applicable electrical specifications before selection.
Product Information & Specifications Complete technical table and diagrams below. Tap the image to enlarge for detailed specifications.
35
BTW SERIES THERMAL FUSE
HOME
EMAIL
Sealing Epoxy
Lead
Ceramic Tube
Special Resin
Thermal Alloy
Lead
Sealing Epoxy
Sealing Epoxy
Lead
Ceramic Tube
Special Resin
Thermal Alloy
Lead
Sealing Epoxy
*
38.5
±
3.0
*
9
±
0
.
2
*
38.5
±
3.0
*
∅
0.55±0.05
*
∅
2
.5±0.0
2
*
∅
0.55±0.05
When fuse body and its ambience temperature rises to the melting point of Thermal fuse, the alloy is
spherical fused under the surface tension of flux, cutting off the circuit and playing a protective role.
CCC
TUV
UL
/
C
-
UL
PSE
certification
Note: Wire length can be customized according to customer requirements.
Tf
Operating
temperature
Th
Tm
(
℃
)
(
℃
)
(
℃
)
(
℃
)
(A)
(V)
Rated Voltage
Rated Current
No.
PN
BTW
115C
BTW 125C
BTW 130C
BTW 135C
BTW 145C
BTW 150C
1
2
3
4
5
6
1
1
1
1
1
1
2
2
2
2
2
2
115
125
130
135
145
150
100
106
108
116
127
126
203
203
203
203
203
200
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
111±2
121±2
125±2
131±2
140±2
144±2
(1) ●=obtained
○
=no obtained
EXPLANATION OF TERMS
Rated Action Temperature
Holding Temperature
Ultimate Temperature
Action Temperature
PARAMETER LIST
KEY FEATURES OF THE PRODUCT
WORKING PRINCIPLE
DIMENSIONS(MM)
Environmentally friendly fusible alloy type
Ceramic case
Accurate functioning temperature
One-time protection; non-resettable
Rated functioning temperature (Tf): the temperature at which the fuse changes its conductive state under the specified test
method. IEC60691, EN60691 and UL60691 require opening within +0/-10°C of the rated functioning temperature. The
Japanese Electrical Appliance and Material Safety Act specifies ±7°C.
Operating temperature: measured at a heating rate of 0.5°C to 1°C per minute with a current below 10mA applied to the fuse
body.
Holding temperature (Th): the highest temperature at which the fuse carries rated current for 168H without changing its
conductive state.
Maximum temperature (Tm): the highest temperature the opened fuse can withstand for 10 minutes without becoming
conductive again.
No. Part No. Tf (℃) Operating temperature (℃) Th (℃) Tm (℃) Rated Current (A) Rated Current Rated Voltage (V) 1 BTW 115C 115 111±2 100 203 1 2 250VAC 2 BTW 125C 125 121±2 106 203 1 2 250VAC 3 BTW 130C 130 125±2 108 203 1 2 250VAC 4 BTW 135C 135 131±2 116 203 1 2 250VAC 5 BTW 145C 145 140±2 127 203 1 2 250VAC 6 BTW 150C 150 144±2 126 200 1 2 250VAC
35
BTW SERIES THERMAL FUSE
HOME
EMAIL
Sealing Epoxy
Lead
Ceramic Tube
Special Resin
Thermal Alloy
Lead
Sealing Epoxy
Sealing Epoxy
Lead
Ceramic Tube
Special Resin
Thermal Alloy
Lead
Sealing Epoxy
*
38.5
±
3.0
*
9
±
0
.
2
*
38.5
±
3.0
*
∅
0.55±0.05
*
∅
2
.5±0.0
2
*
∅
0.55±0.05
When fuse body and its ambience temperature rises to the melting point of Thermal fuse, the alloy is
spherical fused under the surface tension of flux, cutting off the circuit and playing a protective role.
CCC
TUV
UL
/
C
-
UL
PSE
certification
Note: Wire length can be customized according to customer requirements.
Tf
Operating
temperature
Th
Tm
(
℃
)
(
℃
)
(
℃
)
(
℃
)
(A)
(V)
Rated Voltage
Rated Current
No.
PN
BTW
115C
BTW 125C
BTW 130C
BTW 135C
BTW 145C
BTW 150C
1
2
3
4
5
6
1
1
1
1
1
1
2
2
2
2
2
2
115
125
130
135
145
150
100
106
108
116
127
126
203
203
203
203
203
200
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
111±2
121±2
125±2
131±2
140±2
144±2
(1) ●=obtained
○
=no obtained
EXPLANATION OF TERMS
Rated Action Temperature
Holding Temperature
Ultimate Temperature
Action Temperature
PARAMETER LIST
KEY FEATURES OF THE PRODUCT
WORKING PRINCIPLE
DIMENSIONS(MM)
Environmentally friendly fusible alloy type
Ceramic case
Accurate functioning temperature
One-time protection; non-resettable
Rated functioning temperature (Tf): the temperature at which the fuse changes its conductive state under the specified test
method. IEC60691, EN60691 and UL60691 require opening within +0/-10°C of the rated functioning temperature. The
Japanese Electrical Appliance and Material Safety Act specifies ±7°C.
Operating temperature: measured at a heating rate of 0.5°C to 1°C per minute with a current below 10mA applied to the fuse
body.
Holding temperature (Th): the highest temperature at which the fuse carries rated current for 168H without changing its
conductive state.
Maximum temperature (Tm): the highest temperature the opened fuse can withstand for 10 minutes without becoming
conductive again.
Rated Action Temperature Temperature fuses are tested in accordance with the prescribed method to change the temperature of the conductor state. According
to IEC 60691, EN 60691, UL 60691 and other requirements, temperature fuses should be fused within the rated operating temperature
of +0, -10 degree C. The Japanese Electrical Supplies Safety Law stipulates that the temperature fuses should be fused in the range
of +7 degree C. Action Temperature At the heating rate of 0.5 C 1 C per minute, the temperature of the fuse was measured through a current below 10 mA to the product body. Holding Temperature The rated current is applied to the fuse, and the highest temperature measured in continuous 168H is not changed. Ultimate Temperature The temperature fuse will withstand to keep disconnected with the highest temperature after 10 minutes.
35
BTW SERIES THERMAL FUSE
HOME
EMAIL
Sealing Epoxy
Lead
Ceramic Tube
Special Resin
Thermal Alloy
Lead
Sealing Epoxy
Sealing Epoxy
Lead
Ceramic Tube
Special Resin
Thermal Alloy
Lead
Sealing Epoxy
*
38.5
±
3.0
*
9
±
0
.
2
*
38.5
±
3.0
*
∅
0.55±0.05
*
∅
2
.5±0.0
2
*
∅
0.55±0.05
When fuse body and its ambience temperature rises to the melting point of Thermal fuse, the alloy is
spherical fused under the surface tension of flux, cutting off the circuit and playing a protective role.
CCC
TUV
UL
/
C
-
UL
PSE
certification
Note: Wire length can be customized according to customer requirements.
Tf
Operating
temperature
Th
Tm
(
℃
)
(
℃
)
(
℃
)
(
℃
)
(A)
(V)
Rated Voltage
Rated Current
No.
PN
BTW
115C
BTW 125C
BTW 130C
BTW 135C
BTW 145C
BTW 150C
1
2
3
4
5
6
1
1
1
1
1
1
2
2
2
2
2
2
115
125
130
135
145
150
100
106
108
116
127
126
203
203
203
203
203
200
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
111±2
121±2
125±2
131±2
140±2
144±2
(1) ●=obtained
○
=no obtained
EXPLANATION OF TERMS
Rated Action Temperature
Holding Temperature
Ultimate Temperature
Action Temperature
PARAMETER LIST
KEY FEATURES OF THE PRODUCT
WORKING PRINCIPLE
DIMENSIONS(MM)
Environmentally friendly fusible alloy type
Ceramic case
Accurate functioning temperature
One-time protection; non-resettable
Rated functioning temperature (Tf): the temperature at which the fuse changes its conductive state under the specified test
method. IEC60691, EN60691 and UL60691 require opening within +0/-10°C of the rated functioning temperature. The
Japanese Electrical Appliance and Material Safety Act specifies ±7°C.
Operating temperature: measured at a heating rate of 0.5°C to 1°C per minute with a current below 10mA applied to the fuse
body.
Holding temperature (Th): the highest temperature at which the fuse carries rated current for 168H without changing its
conductive state.
Maximum temperature (Tm): the highest temperature the opened fuse can withstand for 10 minutes without becoming
conductive again.
(1) ●=obtained ○=no obtained
For confirmation of specifications, availability and suitable application, please contact our sales team.